Development and Paths of Energy Saving in Water Pumps
1. Development trend of pump energy-saving technology in China
At present, in many electric drive applications at home and abroad, vector-controlled frequency converters have been widely used for stepless speed regulation of AC motors in general machinery, textiles, printing and dyeing, papermaking, steel rolling, chemicals and other industries, and have clearly achieved energy-saving results and met process and automatic speed regulation requirements. However, they have not been fully applied in the fields of fans and pumps. The main reason is insufficient awareness that fan and pump loads can save large amounts of energy. We therefore introduce the energy-saving principles and application status of fans and pumps to customers. Fans and pumps account for more than 60% of industrial electricity consumption nationwide; if frequency converters could be fully used in this field for stepless variable-frequency speed regulation, it would be a strategy for invigorating the country, which is seriously short of electricity while developing its processing and manufacturing industries. A fan is a device for conveying gas. A pump is a device for conveying water or other liquids. In terms of structure and working principle, the two are basically the same. Let us first take a fan as an example. Natural draft cooling towers, circulating water pumps, circulating water pipes and pipe accessories are important components of a power plant's circulating water system. Studying the system scheme and determining the optimal system configuration in the preliminary design of a power plant is of positive significance for reducing construction costs. The core part of circulating water system design is the reasonable selection and configuration of natural draft cooling towers and circulating water pumps; in the construction of the circulating water system they require the most investment and the most complex construction, and have the greatest impact on the total investment of the power plant. They directly affect the unit cost of power engineering construction and the investment recovery period of the power plant. The optimal design of the water supply system is the basis for selecting the system scheme, and the annual cost of the circulating water pump motor has the greatest impact on the scheme design. Under the premise of ensuring safe full-load power generation of the steam turbine, how to reduce the annual cost of the motor is worth considering for every engineering designer.
2. Problems in the use of water pumps
1. Misunderstandings about pump energy saving
In the past, our understanding of pump energy saving was mainly to improve various efficiency indicators of pumps; in fact this is a misunderstanding, a one-sided understanding. The scope of energy saving we refer to is not only an efficiency indicator, but also includes the stability of pump performance, pump life, material savings and other aspects. Furthermore, in the specific use environment of a pump, we must also carry out targeted energy-saving design, such as sealing performance, hydraulic performance and high-temperature resistance, all of which must be designed for different environments and uses. Therefore, research on pump energy saving is very complex work, and our understanding of the concept of energy saving must not be too one-sided but should be comprehensive and holistic.
2. Factors relating to user units and individuals
When purchasing pumps, user units and individuals often focus on whether the pump meets their needs and whether the price is relatively low, but pay little attention to the energy-saving technical indicators of the pump. This consumer demand has also dampened the enthusiasm of pump design and manufacturing units for energy-saving technological innovation. In addition, a large proportion of consumers choose pumps with excessive flow and head margins to ensure that their use needs can be met; the consequence is that the actual operating efficiency of the pump during use is far lower than its maximum efficiency, and it never operates in the high-efficiency range. Moreover, during use, because user units' management and inspection are not strict, operation and maintenance are inappropriate, and repairs are not timely, pumps frequently fail, causing a great deal of energy waste.
3. Technical approaches to pump energy saving
1. Energy saving of the pump itself
In designing and manufacturing pumps, designers and manufacturers must have energy-saving awareness; as pump design and manufacturing units, they have a responsibility to provide consumers with high-efficiency, energy-saving pump products. When designing, the design unit should select excellent hydraulic models and study scientific and efficient hydraulic design methods, and during the design process conduct pump reliability tests and product material selection tests to improve the service efficiency of pump products. During manufacturing, the manufacturer should establish its own enterprise standards higher than national machinery standards and try every means to reduce hydraulic losses. Each process should be strictly controlled during manufacturing to minimize the roughness of flow passage components, carefully treat gaps and appropriately reduce clearance values, so as to improve pump efficiency and achieve the purpose of pump energy saving.
2. Improving energy saving of the pump system
In addition to the energy saving of the pump product itself, we must also attach importance to the development and research of energy-saving technologies for the entire system. The service efficiency of a pump is also closely related to its supporting facilities, and system energy-saving technology is even more important than the energy-saving technology of the pump itself. Research on system energy-saving technology should focus on carrying out system engineering design from the perspective of energy saving, so that all links constituting the system can achieve the best matching effect and the entire pump system can give full play to its maximum service efficiency during operation. This mainly includes the connection between the pump and motor, the design of the pipe network, and the connection and coordination of related accessories, so that they can all play their greatest role, thereby improving the service efficiency and service life of the pump system.
3. Energy saving during pump operation
The efficiency of the pump itself has been improved and the entire pump system has been designed for energy saving, but this is only one aspect; another very important aspect is pump operation. In practice, improper use of pumps often prevents them from performing efficiently, and the use environment of pumps is very complex, with different environments requiring different process flows and process parameters that must be flexibly adjusted during use. For example, when adjusting the pump system, attention should be paid to minimizing energy loss and using throttling regulation as little as possible; the problem can be solved from the angles of blade angle adjustment, speed variation and impeller trimming, so as to ensure that both the motor and the pump work efficiently. When installing the pump, the impeller angle should be adjusted according to the specific use environment for blade angle regulation, and the blade installation angle should be reasonably determined so that the pump can work efficiently. Trimming regulation refers to adjusting pump performance by machining the impeller diameter; it is the simplest and most convenient of the energy-saving measures. A common rule in trimming regulation is that the flow rate, head and shaft power before and after trimming are proportional to the impeller diameter, the square of the diameter and the cube of the diameter respectively. One issue to note when using trimming regulation is that adjustment must be carried out within a safe range and cannot be unlimited. Speed regulation is the most direct and commonly used adjustment method in daily use; it does not produce power loss and directly changes pump performance through changes in pump speed. In daily life the main implementation methods include gearboxes, belt drives, frequency conversion and electric motors. Among these, the most ideal is variable-frequency speed regulation, with the advantages of high efficiency, stepless speed adjustment and a wide speed regulation range, but its disadvantage in application is the relatively high investment.
4. Energy saving by user units and individuals in pump use
In a specific use environment, after a reasonable pump system has been selected, user units and individuals should also establish energy-saving awareness and carry out strict management during operation and use so that the pump can save energy during operation. At the same time, the pump system should be maintained and serviced frequently so that it can be in the best operating state, and problems in the pump system should be found through routine inspection and repaired and maintained, which both extends the service life of the pump system and achieves good energy-saving benefits.
With the development of modern technology, some new design methods and advanced casting and processing techniques have also been applied in production, which have greatly improved pump efficiency and promoted energy-saving work. The problems existing in our current pump energy-saving work will surely be solved as people's awareness increases and technology advances; the prospects for pump energy-saving work are very bright.